<LOGO>
FM Transmitter Measurement Report
Created: 2024-10-17 11-29-41
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 61 dBuV SANDELS
Pilot RDS Phase Difference
5.4 kHz 5.5 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
11 kHz 70 kHz 17681 4,0043
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
1,7 dBr 3,18 dBr 4,5 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 70 kHz MIN: 11 kHz % above 76 kHz: 4,0043 Acquired: 2024/10/17 11.28.37 Total samples: 17681 Equivalent time: 0:14:44 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: 4,5 dBr MIN: 1,7 dBr AVE: 3,18 dBr % above 12,2 dBr: 0,0 Last value: 3,6 dBr (2024/10/17 11.28.37) 11.14 11.16 11.18 11.20 11.22 11.24 11.26 11.28 0 50 100 Dev. MAX [kHz] 0 2 4 Pm [dBr]